Panasonic WV-ASC970 Istruzioni per gli Interventi Pagina 28

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 27
28
■
Other Setup
● Alarms
To trigger alarms, setup the alarm source devices and register them to Alarm Source database by using Admin
Console.
# Alarm Type Alarm Source How to setup Alarm source setup in
Admin Console
1 Camera Motion analog camera Turn on MOTION DET setting in dedicated camera
menu.
Select Motion (cam)
network camera 1.SelectONfornetworkdevice'sVMDalarm.
2.SettheServerIPAddresstonetworkdevices'
alarm notification destination IP Address field.
Also set the port number 1818.
2 I/O Port (Dry con-
tact) alarm
analog digital input port in
SX850 or SX650 cage
Select SX850 or SX650 node and Register the input
port setting to Admin I/O Ports menu
Select I/O Port
network device
(network camera,
network decoder, DVR)
1.SelectONfornetworkdevices'Terminalalarm.
2.SettheServerIPAddresstonetworkdevices'
alarm notification destination IP Address field.
Also set the port number 1818.
Select I/O Port
3 RS232C alarm Externalsystem'sRS232C
I/F
Select RS232 Controller Model for desired port in
Admin Controllers menu
Select RS232
4 Video Loss (any) One of analog cameras via
SX850 or SX650 cage
Turn on Alarm Trigger check box in Admin Cameras
menu.
Select Vid Loss (any)
5 Video Loss (cam) A certain analog camera via
SX850 or SX650 cage
Turn on Alarm Trigger check box in Admin Cameras
menu.
Select Vid Loss (cam)
6 Global Alarm Other domains alarms and
do not care about alarm type
Select one or more than one domain that the global
alarm should be exported in Admin Alarms menu,
Export tab, UNIT partition menu.
Select Global Alarm
7 Scene change
detection
WV-NP1000
WV-NP1004
WV-NW484S
1.SelectONforNP1000'sScenechangedetection
alarm.
2.SettheServerIPAddresstoNP1000'salarmnoti-
fication destination IP Address field. Also set the
port number 1818.
Select Scene Change
(cam)
8 Command alarm network camera 1.SelectONfornetworkdevices'Commandalarm.
2.SettheServerIPAddresstonetworkdevices'
alarm notification destination IP Address field.
Also set the port number 1818.
Select Cmd Alm (cam)
9 Communication
Error (between cam-
era and recorder)
DVR (except RT416) 1. Set the Port number 1818 for Panasonic alarm.
2. Set the Server IP Address to Panasonic alarm
destination IP Address field.
Select Comm Err (cam)
10 Intruder detection WJ-NT314 See the NT314 Network Operating Instructions. Select Intruder (cam)
11 Object detection WJ-NT314 See the NT314 Network Operating Instructions. Select Object dct.
(cam)
12 Capacity Warning DVR (except RT416) 1. Set the Port number 1818 for Panasonic alarm.
2. Set the Server IP Address to Panasonic alarm
destination IP Address field.
Select Capacity Warn
(dvr)
13 RAID Down DVR (except RT416, ND200) 1. Set the Port number 1818 for Panasonic alarm.
2. Set the Server IP Address to Panasonic alarm
destination IP Address field.
Select RAID Down
(dvr)
14 Thermal Error DVR (except RT416) 1. Set the Port number 1818 for Panasonic alarm.
2. Set the Server IP Address to Panasonic alarm
destination IP Address field.
Select Therm Err (dvr)
15 DVR Error
(any of DVR Error)
DVR (except RT416) 1. Set the Port number 1818 for Panasonic alarm.
2. Set the Server IP Address to Panasonic alarm
destination IP Address field.
Select DVR Err (dvr)
16 Face Matching WJ-NV200 1. Set the Port number 1818 for Panasonic alarm.
2. Set the Server IP Address to Panasonic alarm
destination IP Address field.
3. Activate the face matching alarm action.
Select Face Match
(NV200)
Vedere la pagina 27