The Lifespan of the Storage Battery
The storage battery has a limited life. If the
operation time is extremely short after a
proper charge, replace the battery with a
new one. If the tool is not used frequently,
charge the battery at least once in 6 months
to maintain battery performance.
Note: Use under extremely hot or cold
conditions will reduce operation
capacity on a single charge.
(Q) Battery pack release button
(T) Battery capacity indicator
Reading the battery capacity indicator
1. Reading the battery capacity indicator
during use
This indicator displays the remaining
battery capacity for approximately 5
seconds after the trigger is switched off.
Note: The trigger must be fully depressed
for minimum 2 seconds before the
trigger is off in order to get an
accurate reading.
Note: Each LED indicator represents 20%
of battery capacity.
B.m E
Below 20% of capacity
► Charge the battery pack.
Overload indication
This indicator flashes to warn of an
overload of the motor immediately
before it occurs. (The display goes off
when the overload condition is resolved.)
Stop using the tool when this condition
occurs.
2. Reading the battery capacity indicator
during charging.
(3) At the start of charging
Part of the row of LED indicators
lights up, according to the remaining
battery capacity prior to charging.
During charging
As charging progresse, additional
LED indicators light up as the
battery capacity increases.
@ Charging completed
Confirm by the charging lamp(^on
the charger.
3.
(D ® @
Reading the battery capacity indicator by
depressing the button on the battery
pack.
Q) Push the button.
The indicators light up in the
following sequence-
battery temperature LED { 24
-hour charge LED (#-<111) each 0.5
seconds (during which the system
diagnoses the condition of the
battery.)
The row of LED indicator displays
the remaining level of the battery
capacity for approximately 5
seconds.
8